胎儿动脉导管早闭一例

原文传递
导出
摘要 患儿,女,生后6 min,因胎儿心脏超声提示动脉导管早闭(premature closure of the ductus arteriosus,PCDA)于35周+1行剖宫产娩出。患儿系第1胎第1产,胎龄34周+6时院外产科超声提示胎儿心率减慢、心律不齐,后转诊河北省人民医院产科,复查产科超声:三尖瓣开放受限伴大量反流、肺动脉流速减低,心律不齐(频发房早),静脉导管流速增快、S/a高于正常、早搏时a波反向。查胎儿心脏超声:提示PCDA,三尖瓣略增厚伴大量反流,肺动脉流速减低,心律不齐(考虑房性早搏),静脉导管频谱早搏时a波呈反向(见图1)。
出处 《国际儿科学杂志》 2024年第5期356-358,共3页 International Journal of Pediatrics
  • 相关文献

参考文献6

二级参考文献47

  • 1冯琪,李源,王颖,郭在晨.早产儿动脉导管未闭的临床研究[J].实用儿科临床杂志,2005,20(2):129-131. 被引量:15
  • 2蒋世良,黄连军,徐仲英,赵世华,凌坚,郑宏,张戈军,张岩,戴汝平,刘延玲,王云.先天性心脏病介入治疗的严重并发症分析及其防治[J].中国循环杂志,2005,20(1):21-24. 被引量:100
  • 3Nemerofsky SL, Parravicini E, Bateman D, et al. The ductus arteriosus rarely requires treatment in infants > 1000 grams[J]. Am J Perinatol, 2008,25(10):661-666. DOI: 10.1055/s-0028- 1090594.
  • 4Malviya M, Ohlsson A, Shah S. Surgical versus medical treatment with cyclooxygenase inhibitors for symptomatic patent ductus arteriosus in preterm infants[J]. Cochrane Database Syst Rev, 2008,(1):CD003951. DOI: 10. 1002/14651858.CD003951.pub2.
  • 5Eichenwald EC, Stark AR. Management and outcomes of very low birth weight[J]. N Engl J Med, 2008,358(16):1700-1711. DOI: 10. 1056/NEJMra0707601.
  • 6Alagarsamy S, Chhabra M, Gudavalli M, et al. Comparison of clinical criteria with echocardiographic findings in diagnosing PDA in preterm infants[J]. J Perinat Med, 2005,33(2):161-164. DOI: 10.1515/JPM.2005.030.
  • 7Harling S, Hansen-Pupp I, Baigi A, et al. Echocardiographic prediction of patent ductus arteriosus in need of therapeutic intervention[J]. Acta Paediatr, 2011,100(2):231-235. DOI: 10.1111/j. 1651-2227.2010.02027.x.
  • 8Tan HL, Pinder M, Parsons R, et al. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit[J]. Br J Anaesth, 2005,94(3):287- 291. DOI: 10.1093/bja/aei054.
  • 9Stewart GM, Nguyen HB, Kim TY, et al. Inter-rater reliability for noninvasive measurement of cardiac function in children[J]. Pediatr Emerg Care, 2008,24(7):433-437. DOI: 10.1097/PEC.0b013e31817de 143.
  • 10Dey I, Sprivulis P. Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor[J]. Emerg Med Australas, 2005,17(3):193-199. DOI: 10.1111/j.1742 6723.2005.00722.x.