摘要 离岸式小型自然循环铅冷快堆运行在恶劣环境下,且通常少人值守,在这种情况下,传感器故障可能对系统的安全性产生严重影响。为及时检测和诊断传感器故障,提出了一种结合主成分分析(PCA)和支持向量机(SVM)的方法。所提方法基于数据驱动,不需要系统的详细数学模型或特定状态的先验知识。采用PCA方法,能够有效降低数据维度。使用MATLAB/Simulink中构建的小型铅冷快堆动态模型,产生传感器数据,以训练和建立故障诊断模型,并进行了性能测试,验证了所提出的故障诊断方法的准确性和有效性。 The small natural circulation lead-cooled fast reactor operates in harsh environments and is typically left unattended.In such circumstances,sensor failures can have a significant impact on the system safety.To promptly detect and diagnose sensor faults,a method combining the Principal Component Analysis(PCA)and the Support Vector Machine(SVM)is proposed.This data-driven approach eliminates the need for detailed mathematical models of the system or prior knowledge of specific states.By integrating the PCA,it efficiently reduces data dimensions.Using the dynamic model of the small lead-cooled fast reactor built in the MATLAB/Simulink,the sensor data is generated to train and establish the fault diagnosis model,and the test is carried out to verify the accuracy and effectiveness of the proposed fault diagnosis method.
作者 马永健 冯云 孙培伟 魏新宇 MA Yongjian;FENG Yun;SUN Peiwei;WEI Xinyu(School of Nuclear Science and Technology,Xi'an Jiaotong University.Xi'an of Shaanxi Prov.710049,China)
出处 《核科学与工程》 CAS CSCD 北大核心 2024年第2期464-471,共8页 Nuclear Science and Engineering
基金 国家重点研发计划(2020YFB1902101)资助。
关键词 铅冷快堆 传感器故障 故障诊断 主成分分析 支持向量机 Lead-cooled fast reactor Sensor failure Fault diagnosis Principal components analysis Support vector machine
  • 相关文献

参考文献4

二级参考文献44

共引文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部