期刊文献+

基于无线传感技术的变电站开关柜故障自动化监测系统

Automatic Monitoring System for Substation Switchgear Faults Based on Wireless Sensing Technology
下载PDF
导出
摘要 为可靠掌握变电站开关柜的运行状态,保证变电站的稳定运行,该文设计基于无线传感技术的变电站开关柜故障自动化监测系统。传感节点采集开关柜运行数据,组建分层分簇的无线传感网络,结合能量-周期更新机制,采用双簇头的传输方式传输采集的开关柜运行数据,利用概率神经网络实现开关柜故障自动化诊断,输出故障类别结果。测试结果显示,无线传感网络中节点覆盖率以及网络区域连通率均在93.34%以上,各个节点接收功率的热力分布情况均匀,可以实现开关柜故障的频率可视化。 To reliably grasp the operation status of the substation switchgear and ensure the stable operation of the substation,a substation switchgear fault automation monitoring system based on wireless sensing technology is designed.Sensor nodes collect operating data of switchgear,construct a layered and clustered wireless sensor network,and combine the energy cycle update mechanism to transmit the collected operating data of switchgear using a dual cluster head transmission method.Probabilistic neural networks are used to achieve automatic diagnosis of switchgear faults and output fault category results.The test results show that the node coverage and network area connectivity in the wireless sensor network are both above 93.34%.The thermal distribution of power received by each node is uniform,which can achieve fault category classification and frequency visualization of switchgear faults.
作者 吴寒江 赵志山 史鑫 王剑 WU Hanjiang;ZHAO Zhishan;SHI Xin;WANG Jian(Langfang Power Supply Company,State Grid Jibei Electric Power Co.,Ltd.,Langfang 065000,China;School of Electrical Engineering,Shandong University,Jinan 250100,China)
出处 《自动化与仪表》 2024年第7期79-83,共5页 Automation & Instrumentation
基金 国网冀北电力有限公司科技项目(JB23-QTFW-2B4-012314)。
关键词 无线传感技术 变电站 开关柜故障 自动化监测 传输协议栈 分层分簇 wireless sensing technology substation switch cabinet malfunction automated monitoring transport protocol stack hierarchical clustering
  • 相关文献

参考文献10

二级参考文献133

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部