泄漏电流监测法是对氧化锌避雷器进行在线监测及状态诊断的有效方法,但避雷器承受电压存在谐波干扰时,传统泄漏电流特征量会出现效果不理想的问题。为了提高谐波干扰下避雷器运行状态诊断的准确率,在对避雷器泄漏电流特性分析的基础上,提出一种基于泄漏电流时间积分的新型特征量,并对该特征量的原理进行理论分析。提出特征量对于避雷器状态区分能力的评估指标,通过与其他传统特征量的实验比较分析,结果表明,所提出的泄漏电流时间积分新特征量具有更好的有效性和优越性,且抗谐波干扰能力更强,可在不同谐波电压干扰下很好地区分氧化锌避雷器的运行状态。
The leakage current monitoring method is an effective method for online monitoring and status diagnosis of zinc oxide arrester.But when there is harmonic interference in the voltage of the arrester,the effect of traditional leakage current feature is not ideal.In order to improve the diagnostic accuracy of arrester operating status under harmonic interference,based on the analysis of leakage current characteristics of arrester,a new feature based on leakage current time integral is proposed,and the principle of the feature is analyzed theoretically.The evaluation index of feature for the state distinguishing ability of the arrester is proposed.Through comparative analysis with other traditional feature,the results show that the new feature measurement of leakage current time integral proposed in this paper has better effectiveness and superiority,and the ability to resist harmonic interference is stronger,it can distinguish the operation status of zinc oxide arrester under different harmonic voltage interference.
作者
巩彦江
郑爽
包添庆
杨润冰
叶宝柱
GONG Yanjiang;ZHENG Shuang;BAO Tianqing;YANG Runbing;YE Baozhu(Tangshan Power Supply Company of State Grid Jibei Electric Power Company Limited,Tangshan 063000,China)
出处
《微型电脑应用》
2024年第7期52-55,共4页
Microcomputer Applications
基金
国网冀北电力有限公司科技项目(5201031900TM)。
关键词
氧化锌避雷器
泄漏电流
在线监测
特征量
谐波
zinc oxide arrester
leakage current
online monitoring
feature
harmonic