期刊文献+

基于Flowmaster的小流量供水设备调节性能模拟

Flowmaster-based Simulation of Regulation Performance of Low Flow Water Supply Equipment
下载PDF
导出
摘要 现有的二次供水研究对小流量工况关注较少,小流量工况下主泵低效运行、频繁启停问题正成为制约城市供水“最后一公里”低能耗、高质量发展的痛点。为此,建立Flowmaster仿真模型对“工频辅泵+气压罐”小流量供水模式进行模拟,探究了需求侧不同小流量下气压罐的调节性能。结果表明,“工频辅泵+气压罐”可很好减少水泵启停次数,保持系统稳定。进一步研究了气压罐预充压力对调节性能的影响,阐明了预充气泄漏带来的负面影响,并提出相关工程建议。 Existing secondary water supply research on small flow conditions is less be attention,small flow conditions of inefficient operation of the main pump,frequent start-stop problem is becoming a constraint on the urban water supply"last kilometer"low energy consumption,high-quality development of the pain point.The Flowmaster simulation model is established to simulate the low-flow water supply mode of"power frequency auxiliary pump+air pressure tank"to investigate the regulation performance of the pneumatic tank under different flow rates on the demand side.The results show that the"power frequency auxiliary pump+air pressure tank"can reduce the number of pump starts and stops and maintain the stability of the system.Furthermore,the influence of pre-filling pressure of air pressure tank on the regulation performance is studied,the negative impact of pre-filling leakage is elucidated.The relevant engineering recommendations are put forward.
作者 陈佳中 王彤 尚渝钧 曹仙桃 尚鑫宇 宋佳奇 王文成 郭小宝 CHEN Jia-zhong;WANG Tong;SHANG Yu-jun;CAO Xian-tao;SHANG Xin-yu;SONG Jia-qi;WANG Wen-cheng;GUO Xiao-bao(School of Architecture Engineering,Chang’an University,Xi’an 710061,China;PowerChina Northwest Engineering Corporation Limited,Xi’an 710065,China;Xi’an Domestic Water Secondary Distribution Center,Xi’an 710016,China;Chinaust Plastics Corp.Ltd.,Zhuozhou 072761,China)
出处 《水电能源科学》 北大核心 2024年第7期151-154,141,共5页 Water Resources and Power
基金 西安市二次供水“互联网+”监管体系应用(2022-S80)(2022)。
关键词 Flowmaster 小流量 工频辅泵+气压罐 调节性能 二次供水 Flowmaster small flow power frequency auxiliary pump+air pressure tank tuning performance secondary water supply
  • 相关文献

参考文献2

二级参考文献5

  • 1CJJ140-2010二次供水工程技术规程.
  • 2夏伟光.对《微机控制变频调速给水设备》修订的有关内容解读.见:2011年中国建筑给排水技术高峰论坛论文集,2011.203-206.
  • 3CJ/T 352-2010微机控制变频调速给水设备.
  • 4中国建筑标准设计研究院.全国民用建筑工程设计技术措施节能专篇给水排水(2007年版).北京:中国计划出版社,2007.
  • 5中国建筑标准设计研究院.全国民用建筑工程设计技术措施给水排水(2009年版).北京:中国计划出版社,2009.