摘要 为实现中国民航业的绿色可持续发展,中国政府提出了打造绿色低碳航空、提高服务保障能力、推进技术进步和节能减排等要求,对中央空调系统能效有更高的要求。对于新建航站楼,通过节能措施提升系统的整体能效是关键所在。文章以我国夏热冬暖地区枢纽机场航站楼为例,主要从中央空调系统的水系统方面开展研究,开展能效分析,提出节能措施,既为新航站楼中央空调的建设提供参考依据,又为现有航站楼中央空调系统的改造提供数据支持。 In order to achieve the green and sustainable development of Chinese civil a-viation transportation industry,the Chinese government have put forward requirements such as building green and low-carbon aviation,improving service guarantee capabilities,Promoting technological progress,and energy conservation and emission reduction,which have higher requirements for the energy efficiency of central air-conditioning systems.For newly built airport terminals,energysaving measures is important to improv the overal!energy efficiency of central air-conditioning systems.This paper is based on the newly built hub airport terminal in hot summer and warm winter zone of China as an example,through deep analysis of the energy consumption of water system,we provide energy-sav ing measures for the construction of the newly built terminal and data support for the transformation of the existing terminal.
作者 李哲青 温嘉权 沈浩 邓杰文 廖展浩 Li Zheqing;Wen Jiaquan;Shen Hao;Deng Jiewen;Liao Zhanhao(Guangzhou Baiyun International Airport Co.,Ltd.;Tsinghua University;Guangzhou Latitude Energy Technology Development Co.,Ltd.)
出处 《制冷与空调》 2024年第6期55-61,共7页 Refrigeration and Air-Conditioning
关键词 机场航站楼 空调系统 能效优化 节能 高效机房 airport terminal central air-conditioning system energy efficiency energy saving high efficient chiller plant
  • 相关文献

参考文献6

二级参考文献45

共引文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部