摘要
为提高热泵型房间空调器的全年能源消耗效率,通过理论分析及试验验证,明确压缩机适配性的优化设计方法。通过合理控制压缩机油池温度,实现空调器低温制冷-中间工况的能效提高2.9%,全年能源消耗效率提高5.3%,满足压缩机系统适配性需求。
In order to improve the annual energy efficiency(APF)of heat pump room air conditioner,the optimal design method of compressor adaptability is clarified through theoretical analysis and experimental verification,By reasonably controlling the tempera-ture of the compressor oil pool,the energy efficiency of the low temperature refrigeration intermediate working condition of the air conditioner is increased by 2.9%,and the APF is increased by 5.3%,which meet the adaptability requirements of compressor systems.
作者
伦成钢
王鹏
孙民
Lun Chenggang;Wang Peng;Sun Min(Xi'an Qing'an Refrigeration Equipment Co.,Ltd.)
出处
《制冷与空调》
2024年第6期89-91,96,共4页
Refrigeration and Air-Conditioning
关键词
房间空调器
压缩机
直流调速
油池温度
适配性
room air conditioner
compressor
DC speed regulating
oil pool temperature
adaptability