针对某电厂1 000 MW发电机组转子振动大的现象,从该型号转子结构的特点出发,发现转子振动呈增大的趋势,着重描述了抽出转子和返厂检修发现的不正常情况,并进一步分析原因,提出处理措施,处理后转子运行良好,振动情况满足规程要求。
In view of the phenomenon of large rotor vibration of 1000 MW generator set in a power plant,starting from the characteristics of the rotor structure of this model,it is found that the rotor vibration is increasing,and the abnormal situation found in the extraction of the rotor and the return to the factory for maintenance is emphatically described,and the causes are further analyzed,and the treatment measures are proposed,and the rotor runs well after treatment,and the vibration meets the requirements of the regulations.
作者
周志凯
ZHOU Zhi-kai(Guangdong Electric Power Development Co.,Ltd.,Guangzhou,Guangdong 510000)
出处
《江西电力职业技术学院学报》
CAS
2024年第3期13-15,共3页
Journal of Jiangxi Vocational and Technical College of Electricity
关键词
发电机转子
振动增大
阻尼条风孔错位
阻尼条拱翘变形
Generator Rotor
Increased Vibration
the Damping Strip Air Hole is Misaligned
the Arch of the Damping Bar is Warped and Deformed