期刊文献+

“华龙一号”余热排出系统氧化运行期间对周边区域的影响分析

Analysis of the effect of residual heat removal system on the surrounding area during oxygenation in HPR1000 reactor
下载PDF
导出
摘要 余热排出系统的辐射水平在机组停堆过程中会明显变化,氧化运行期间达到停堆峰值,对周边区域产生影响。对“华龙一号”余热排出系统停堆峰值时刻周边区域的辐射水平进行了计算,对比运行电厂实测最大值,综合分析给出了余热排出系统对周边区域辐射水平的影响,同时提出了相应的优化建议。 The radiation level of residual heat removal system will change significantly during reactor shutdown,and will reach the shutdown peak during oxygenation,which will affect the surrounding area.In this paper,the surrounding area radiation level of the HPR1000 residual heat removal system is calculated and compared with the measured maximum value.The influence on the radiation level in the surrounding area of residual heat removal system is analyzed comprehensively,and the corresponding optimization suggestions are put forward.
作者 李明 石生春 庞宗柱 刘宇 蒋颜蔓 LI Ming;SHI Shengchun;PANG Zongzhu;LIU Yu;JIANG Yanman(Nuclear and Radiation Safety Center,Ministry of Ecology and Environment,Beijing 100082)
出处 《辐射防护》 CAS CSCD 北大核心 2024年第4期403-409,共7页 Radiation Protection
关键词 “华龙一号” 余热排出系统 氧化运行 停堆峰值 HPR1000 residual heat removal system oxygenation shutdown peak
  • 相关文献

参考文献9

二级参考文献34

  • 1毛亚蔚,赵博.秦山核电二期工程冷停堆放射性峰值效应对化容系统净化设备的屏蔽设计影响[J].辐射防护通讯,2004,24(5):11-14. 被引量:3
  • 2Burrill K A.关于堆内水化学与腐蚀产物沉积的综合实验研究[J].英国核能学会,反应堆系统水化学,1977.
  • 3Odar S. Fundamental Aspects of Water Chemistry in the Primary System of PWRs[M]. Paris, AREVA, 2007.
  • 4Cohen E Water Coolant Technology of Power Reactors, Gordon and Breach[M]. New York, 1969.
  • 5[1]Cold shutdown with primary circuit oxygenation. Training file of EDF*SPT
  • 6Sanmen Nuclear Power Company Ltd. Sanmen nuclear power plant phasel units 1&2 preliminary safety analyses report[ R ]. 2008.
  • 7Taishan Nuclear Power Company Ltd. Taishan nuclear power plant phasel units l&2 preliminary safety Analyses Report[R]. 2009.
  • 8Rocher A. Bergcr M.LImpact of main radiological pollutants on contamination risks (ALARA) optimization of physico chemical environment and retention technics during operation and shutdown [ C ]. EDF,Portoroz Workshop. Session 2.2004.
  • 9AREVA( 阿海珐集团 ). Reactor coolant chemical characteristics and specifications. Taishan Nuclear Power Station(Rev.A)[ R ]. 2008.
  • 10王琳.秦山第二核电厂1和2号机组长循环燃料管理论证[R].一回路水化学论证报告.2009.