摘要
文章按照GB/T 35931—2018《棉纤维棉结和短纤维率测试方法光电法》,利用设备XJ129L快速短纤维率测试仪对检验过程中棉纤维短纤维率检验结果的影响因素进行总结,提出改进措施,以提高检验数据的准确性。
The factors that affect the results of cotton short fiber rate inspection during the inspection process using the equipment XJ129L rapid short fiber rate tester was summarized in this paper,which in accordance with the GB/T 35931—2018 Test method for neps and short fiber content of cotton fibers-Photoelectric analyser,in order to improve the accuracy of the inspection data.
作者
耿苗苗
张锡科
张静静
高增兴
邵嘉嘉
胡卫婕
陈小兵
Geng Miaomiao;Zhang Xike;Zhang Jingjing;Gao Zengxing;Shao Jiajia;Hu Weijie;Chen Xiaobing(Weifang Product Quality Inspection Institute,Weifang 261031,China;Qingdao Product Quality Testing Research Institute,Qingdao 266000,China)
出处
《山东纺织科技》
2024年第3期32-33,共2页
Shandong Textile Science & Technology
关键词
短纤维
短纤维率
检验设备
温度
湿度
short fiber
short fiber rate
inspection equipment
temperature
humidity