期刊文献+

电除尘器锯齿线电场在线恢复技术研究

Online Restoration Technology for Zigzag Wire Electrical Field in Electrostatic Precipitators
下载PDF
导出
摘要 锯齿线电场内部短路在线恢复技术是一种安全、可靠、经济、简便且有效的方法,利用外部多台电焊机与短路电场阴极相连,采用大电流快速熔断短路的锯齿线,无需机组停机检修,可大大降低经济损失,目前已在江苏某百万机组电厂多次应用,并且成功率在98%以上。 The online restoration technology for internal short circuits in the zigzag wire electrical field of electrostatic precipitators is a safe,reliable,economical,and convenient method.Multiple external electric welding machines are connected to the short-circuited cathodes of the electrical field,and high currents are used to quickly fuse the short-circuited zigzag wires.This method does not require the owner to stop the operation and maintenance,effectively reducing economic losses.It has been successfully applied multiple times in a million-unit power plant in Jiangsu province,with a success rate of over 98%.
作者 陈祥云 斯高峰 周蔡宇 CHEN Xiangyun;SI Gaofeng;ZHOU Caiyu(Zhejiang Lianzhong Environmental Protection Co.,Ltd.,Zhuji 311899,Zhejiang Province,China)
出处 《电力与能源》 2024年第3期368-369,388,共3页 Power & Energy
关键词 电除尘器 锯齿线 内部短路 electrostatic precipitator zigzag wire internal short circuit
  • 相关文献

参考文献2

二级参考文献23

  • 1郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第十五届中国电除尘学术会议论文集.2013.
  • 2YOSHIO Nakayama,SATOSHI Nakamura,YASUHIRO Takeuchi,et al.MHI high efficiency system-proven technology for mul.
  • 3MASAMI Kato,TADASHI Tanaka,YASUKI Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA.
  • 4土屋喜重,川西好光,大西召一,等.Very cold electrostatic technology of advanced flue gas treatment system for co.
  • 5柳生隆志,土屋喜重,大西召一,等.Recent electrostatic precipitation technology[J].三菱重工技报,1996,33(1):69-73.
  • 6Development and demonstration of waste heat integration with solvent process for more efficient CO2 removal f.
  • 7柴田宪司,三重野光博,山本卓也.電気集麈方法[P].三菱重工技报.2000.
  • 8TOSHIAKI Misaka,YOSHIHIKO Mochizuki.Recent application and running cost of moving electrode type electrostati.
  • 9STEPHENL Francis,ANDREAS Back,PER Johansson.Reduction of rapping losses to improve ESP performance[C]//11th I.
  • 10森雄介,積田佳満,松本有夫,等.Operation results of IHI flue gas desulfurization system-unit No.1 (1 000 MW) of.

共引文献123

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部