期刊文献+

天津宝坻新台FHD-2B质子矢量磁力仪运行质量和干扰分析

OPERATION QUALITY AND INTERFERENCE ANALYSIS ON TIANJIN BAODI NEW TERRACE FHD-2B PROTON VECTOR MAGNETOMETER
下载PDF
导出
摘要 以天津宝坻新台FHD-2B质子矢量磁力仪为例,分析了其运行质量和干扰情况。从观测数据的连续率和有效率,观测数据背景噪声和数据一致性,数据变化动态及主要干扰等方面进行了分析研究。结果表明:宝坻新台地磁FHD观测数据的连续性和有效率较高;仪器背景噪声较大,高于全台网噪声平均值;在日常观测中,主要受到高压直流输电、地磁暴和主机故障等干扰。研究结果对同类台站同类仪器数据分析应用具有借鉴意义。 Taking Tianjin Baodi New Terrace FHD-2B proton vector magnetometer as an example,the instru-ment observation principles and performance indicators are introduced,and the operation quality and interfer-ence are analyzed.This article conducts analysis and research from observation data continuity and effective-ness,observation of data background noise and data consistency,data change dynamics and main interfer-ence.The results of the study show that the continuity and efficiency of the observation data of the Geopagnetic FHD observation of the new platform;the instrument has a large background noise,which is higher than the average of the full-scale network noise;in daily observation,it is mainly subject to high-voltage DC trans-mission,geomagnetic storms,and host failures.Interference.Provide reference for the analysis of similar in-struments of similar stations.
作者 赵黎明 龚永俭 张聪聪 李越 ZHAO Liming;GONG Yongjian;ZHANG Congcong;LI Yue(Baodi Earthquake Monitoring Center Station of Tianjin Earthquake Agency,Tianjin 301800,China;Linfen Central Seismological Station of Shanxi Earthquake Agency,Linfen 041000,China)
出处 《高原地震》 2024年第2期21-27,共7页 Plateau Earthquake Research
基金 天津市巨灾防范工程(项目编号:JZFF-1-1、JZFF-1-2)资助。
关键词 FHD-2B质子矢量磁力仪 运行质量 环境干扰 FHD-2B proton vector magnetometer Operating quality Environmental interference
  • 相关文献

参考文献17

二级参考文献257

共引文献119

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部