期刊文献+

石化库区防雷防静电接地一体化设计

Integrated Design of Lightning Protection and Electrostatic Grounding in Petrochemical Reservoir Area
下载PDF
导出
摘要 石化企业储罐因遭受雷击导致火灾爆炸类事故频发,造成严重损失。结合近年石油库项目设计经验,探讨通过增加雷电预警系统与接地电阻在线监测系统,完善库区防雷防静电接地一体化设计。 Due to lightning strikes,fire and explosion accidents occur frequently in storage tanks of petrochemical enterprises,resulting in serious losses.Based on the design experience of oil depot project in recent years,this paper discusses how to improve the integrated design of lightning protection and electrostatic grounding in reservoir area by adding lightning warning system and grounding resistance online monitoring system.
作者 田飞 TIAN Fei(Cnooc Petrochemical Engineering Co.,Ltd.,Qingdao 266000,China)
出处 《电工技术》 2024年第S01期242-244,共3页 Electric Engineering
关键词 雷电预警系统 接地电阻在线监测系统 安全管理一体化 lightning warning system earth resistance online monitoring system security management integration