烟气连续监测系统在加热炉的运用探讨

Discussion on Application of Flue Gas Continuous Monitoring System in Heating Furnace
下载PDF
导出
摘要 描述了烟气连续监测系统在加热炉上的综合运用。为实现加热炉烟气中气态污染物(SO_(2)、NO_(X)、O_(2))和颗粒物浓度,温度、压力、流量和湿度等参数在操作台上在线监测,通过在烟气分析室内新增S7-300PLC系统建立通讯,实现烟气连续监测数据实时传输至上位机,在加热炉燃烧系统新增画面上显示及智能预警、报警,实现与加热炉的工艺燃烧的联锁控制。 This paper describes the comprehensive application of flue gas continuous monitoring system in heating furnace.In order to realize the online monitoring of gaseous pollutants(SO_(2),NO_(X),O_(2))and particulate matter concentration,temperature,pressure,flow rate and humidity in the flue gas of the heating furnace on the operating table,a new S7-300 PLC system is added to the flue gas analysis room to establish communication.As a result,the real-time transmission of flue gas continuous monitoring data to the host computer is realized,and displaying,intelligent early warning and alarming on the new-added screen of the heating furnace combustion system are realized,so as to realize the interlocking control with the process combustion of the heating furnace.
作者 黎永恒 Li Yongheng(Equipment Power Department of Fujian Sangang Minguang Co.,Ltd.,Sanming 365000,Fujian,China)
出处 《冶金设备管理与维修》 2024年第4期53-56,共4页 Metallurgical Equipment Management and Maintenance
关键词 加热炉 烟气连续监测系统 智能预警 报警 heating furnace flue gas continuous monitoring system intelligent early-warning alarm