期刊文献+

电感耦合等离子体-原子发射光谱法测定铜精矿有害元素的不确定度评定

Evaluation of Uncertainty in the Determination of Harmful Elements in Copper Concentrate by Inductively Coupled Plasma Atomic Emission Spectroscopy
下载PDF
导出
摘要 本文采用电感耦合等离子体-原子发射光谱法(ICP-OES)测定铜精矿有害元素,并对测量结果进行不确定度评定,分别对重复测量和定容体积、工作曲线和标准溶液的稀释、试样称量、电感耦合等离子体发射光谱仪等影响测量不确定度的分量进行分析,为测定铜精矿有害元素的不确定度评定提供依据。 This article describes the use of inductively coupled plasma optical emission spectroscopy(ICP-OES)to determine the levels of harmful elements in copper concentrate.It also discusses the assessment of measurement uncertainty by considering factors such as repeatability,volume adjustment,working curves,dilution of standard solutions,sample weighing,and the influence of the inductively coupled plasma optical emission spectrometer.These analyses provide a basis for the evaluation of uncertainty in the determination of harmful elements in copper concentrate.
作者 裘金燕 胡芬静 唐波英 芦明巧 QIU Jinyan;HU Fenjing;TANG Boying;LU Mingqiao(Zhoushan Customs Comprehensive Technical Service Center,Zhoushan 316000,China)
出处 《品牌与标准化》 2024年第5期7-10,共4页
关键词 铜精矿 有害元素 电感耦合等离子体-原子发射光谱法 不确定度 copper concentrate harmful elements inductively coupled plasma emission spectroscopy uncertainty
  • 相关文献

二级参考文献8

  • 1中国金属学会分析测试分会.CSM01010104--2006电感耦合等离子体发射光谱法测量结果不确定度评定规范[s].
  • 2中国合格评定国家认可委员会.CNAS--CL07测量不确定度评估和报告通用要求[s].
  • 3中国合格评定国家认可委员会.CNAS--GL05测量不确定定度要求的实施指南[s].
  • 4李正东.测量不确定度评定与表示简明教材[M].北京:中国计量科学研究院.
  • 5中国实验室国家认可委员会.CNAL/AG07:2002化学分析中不确定度评估指南[s].
  • 6JJF1059—1999.测量不确定度评定与表示[S].[S].,..
  • 7中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..
  • 8JJG 196—1990常用玻璃量器[S].