摘要 优化了全自动化凯氏定氮仪测定婴幼儿奶粉粗蛋白含量的前处理条件。探究了样品含量、催化剂配比、浓硫酸投加量、消化温度、消化时间等因素对粗蛋白质含量测定的影响。实验得到了最好的前处理条件:样品量1.0 g,催化剂质量配比为8∶0.5,浓硫酸加入量为12.0 mL,消化温度/时间为200℃(20 min)、300℃(20 min)、420℃(80 min)。平行测定结果的标准偏差为0.54%,加标回收率超过99%。奶粉中粗蛋白含量经优化前处理条件测定,精密度高、稳定性好,测定结果与外包装标注接近一致,达到国家乳制品蛋白含量标准。 The pretreatment conditions for the determination of crude protein content in infant milk powder by automatic Kjeldahl nitrogen analyzer were optimized.The effects of sample size,catalyst ratio,concentration of sulfuric acid,digestion temperature and digestion time on the determination of crude protein content were investigated.The optimal pretreatment conditions were as follows:sample size 1.0 g,catalyst mass ratio 8∶0.5,concentration sulfuric acid addition amount 12.0 mL,digestion temperature and time:200℃(20 min),300℃(20 min),420℃(80 min).The standard deviation of parallel determination results was 0.54%,and the recovery rate was over 99%.The content of crude protein in milk powder was determined by optimized pre-treatment conditions with high precision and good stability.The results were close to the content marked on the outer package,which was in line with the national dairy protein content standard.
作者 杨利君 李婧 李云倩 王馨 王恒 侯晓晶 Yang Lijun;Li Jing;Li Yunqian;Wang Xin;Wang Heng;Hou Xiaojing(Xi′an Northwest Institute of Nonferrous Geology Co.,Ltd.,Xi′an 710054,China)
出处 《山东化工》 CAS 2024年第15期184-186,共3页 Shandong Chemical Industry
关键词 全自动凯氏定氮仪 婴幼儿奶粉 粗蛋白含量 automatic Kjeldahl nitrogen analyzer infant milk crude protein content
  • 相关文献

参考文献1

二级参考文献3

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部