摘要
针对现有方法存在自动检测耗时较长的问题,提出基于单片机的三相电能表错接线自动检测方法。首先构建互感环境,采用关联的方式打破检测范围受到的限制,并部署关联检测节点。然后以此为基础,设计三相电能表错接线自动检测模型,采用自适应跟踪测定实现自动检测处理。结果表明,应用所提方法,自动检测平均耗时均被控制在0.65 s以下,应用效果较好,具有一定的应用价值。
Aiming at the problem that the existing method takes a long time to detect automatically,an automatic detection method based on single-chip microcomputer for the wrong wiring of three-phase electricity meter is proposed.Firstly,build a mutual inductance environment,use the association mode,break the limitation of the detection range,and deploy the associated detection nodes.Based on this,the automatic detection model of three-phase electricity meter is designed,and the automatic detection process is realized by adaptive tracking measurement.The results show that the average time of automatic detection is controlled below 0.65 s by using the proposed method,which has good application effect and certain application value.
作者
何义赟
单永梅
陈义林
夏靖
HE Yiyun;SHAN Yongmei;CHEN Yilin;XIA Jing(Anhui NARI Zenith Electricity&Electronic Co.,Ltd.,Hefei,Anhui 230088,China)
出处
《自动化应用》
2024年第15期213-214,218,共3页
Automation Application
基金
安徽南瑞中天电力电子有限公司科技项目“基于人工智能的三相电能表错接线智能诊断技术研究与应用”(524636240007)。
关键词
三相电能表
错接线
自动检测
电能控制
three-phase electricity meter
miswiring
automatic detection
electric energy control