摘要
针对循环水泵GA2802B振动过大的问题开展振动信号诊断,分析结果表明该振动与流体扰动产生的激振力有关,通过理论计算和现场实测相结合,发现该泵处于“超流量”的情况,偏离了设计工况,同时抗汽蚀性能减弱。文章采用三元流叶轮优化改造方式,彻底解决了泵振动过大的问题,同时实现良好的节能效果,既确保了装置的安稳生产,又产生显著的经济效益,可为同类型装置提供参考。
A vibration signal diagnosis was carried out for the high vibration problem of the circulating water pump GA2802B.The analysis results showed that the vibration was related to the excitation force generated by fluid disturbance.Through theoretical calculation and on-site measurement,it was found that the pump was in an“excessive flow”situation,deviating from the design operating point,and its anti-cavitation performance was weakened.This article adopts the transformation method of three-dimensional flow impeller,which completely solves the problem of high vibration and also achieves good energy-saving effects.It not only ensures stable production of the device,but also generates significant economic benefits,providing important reference for similar devices.
作者
沈国峰
刘泽攀
Shen Guofeng;Liu Zepan(SINOPEC Shanghai Petrochemical Co.,Ltd.,Shanghai 200540)
出处
《石油化工技术与经济》
CAS
2024年第4期43-47,共5页
Technology & Economics in Petrochemicals
关键词
循环水泵
振动大
频谱分析
汽蚀
三元流
节能
water circulating pump
high vibration
spectral analysis
cavitation
three-dimensional flow
energy conservation