探讨储能系统中的电弧检测与保护方法,提出一种基于时域触发加频域保护的电弧检测算法。首先,设计了包括自检、增益及滤波电路在内的电弧检测硬件,通过隧穿磁阻效应(TMR)电流传感器放大储能系统拉弧后的电流峰峰值变化差异。其次,利用延时滑窗法提取时域特征作为电弧检测算法的触发条件,触发后计算其频域特征输入电弧检测模型,判定其为真实拉弧后,储能系统立刻进行关机动作。算法的测试结果表明,该方法能够准确识别出串联回路下的储能系统电弧故障,检测准确率100%,能够满足实际应用中的需求。
To investigate arc detection&protection methods in ESSs,an arc detection algorithm based on time-domain triggering and frequency-domain protection is proposed.Firstly,an arc detection hardware was designed,including self-check,gain,and filtering circuits.This hardware amplifies the peak-to-peak current variation difference after an arc occurs in the energy storage system,through the use of a TMR current sensor.Secondly,time-domain features are extracted using a delayed sliding window method for use as trigger conditions in the arc detection algorithm.Once triggered,frequency-domain features are calculated and input into the arc detection model.If it is determined to be a genuine arc event,the ESS immediately performs a shutdown action.The test results of the algorithm show that this method can accurately identify the arc faults in the energy storage system under series circuits,with a detection accuracy rate of 100%,meeting the requirements for practical applications.
作者
张弦
张然
侯鹏
刘孝宇
ZHANG Xian;ZHANG Ran;HOU Peng;LIU Xiaoyu(SUNGROW(Jiangsu)Co.,Ltd.,Nanjing 210000,China;SUNGROW Power Supply Co.,Ltd.,Hefei 230000,China)
出处
《电器与能效管理技术》
2024年第8期91-99,共9页
Electrical & Energy Management Technology
关键词
储能系统
安全
电弧检测技术
电弧检测模型
ESSs
safety
arc detection and protection techniques
arc detection model