摘要
营养盐是海洋调查中必不可少的测量参数。利用流动注射分析仪测定海水营养盐含量通常需要使用与样品盐度相近的人工海水或陈化天然海水作为配制标准曲线的基液和间隔样品的载液。本文测定了Sigma、Aladdin、国药优级纯氯化钠盐溶液和陈化西太平洋海水中亚硝酸盐、硝酸盐、铵盐、磷酸盐及硅酸盐含量的本底值。结果表明:三个品牌的氯化钠盐溶液中除磷酸盐外,亚硝酸盐、硝酸盐、铵盐和硅酸盐的含量均有不同程度的本底值,而陈化西太平洋海水除了亚硝酸盐和硅酸盐外,其它三项营养盐在测定误差范围内基本不存在本底值。
Nutrient assay is essential in the routine oceanographic surveys.The nutrients of seawater are determined on a continuous flow analyzer usually requires artificial seawater or aged low-nutrient natural seawater as the basal solution of standard calibration and the rinsing solution of the assaying system when seawater sample is changed.In this study,the concentrations of components(phosphate,nitrite,nitrate,ammonia nitrogen and silicate)in Sigma,Aladdin and Sinopharm sodium chloride(GR grade)solutions and aged West Pacific seawater were determined.The results showed that the concentrations of nitrite,nitrate,ammonia nitrogen and silicate varied in the three commercial sodium chloride salt solutions except phosphate.In contrast,the concentration of silicate was relatively high and trace amount of nitrite was found while the other three nutrients were not detectable in the aged West Pacific seawater.
作者
任宏伟
陈立朝
胡玉斌
REN Hongwei;CHEN Lichao;HU Yubin(Institute of Marine Science and Technology,Shandong University,Qingdao 266237,China;Key Laboratory of Land and Sea Ecological Governance and Systematic Regulation,Shandong Academy for Environmental Planning,Jinan 250101,China)
出处
《海洋湖沼通报(中英文)》
CSCD
北大核心
2024年第4期130-134,共5页
Transactions of Oceanology and Limnology
基金
国家重点研发计划(2020YFA0608304)
海洋负排放国际大科学计划。
关键词
海水营养盐
陈化海水
盐效应
流动注射分析仪
seawater nutrient concentration
aged seawater
salt effect
continuous flow analyzer