摘要 腹膜透析机是肾病患者的生命维持设备,在临床和医学研究领域占据着十分重要的地位,其技术性能的优劣将直接影响医疗质量,关乎病人身体健康和生命安全。为保证腹膜透析机的计量性能准确可靠,解决腹膜透析机关键参数的溯源问题,本文对腹膜透析机的计量特性、校准条件、校准项目、校准方法和不确定度等项目进行了研究。 Peritoneal dialysis machine is a life support equipment for kidney disease patients,occupying a very important position in clinical and medical research fields.The quality of its technical performance will directly affect the quality of medical treatment,which is related to patients'physical health and life safety.To ensure the accurate and reliable metrological performance of peritoneal dialysis machines and solve the traceability problem of key parameters of peritoneal dialysis machines,this article studies the metrological characteristics,calibration conditions,calibration items,calibration methods,and uncertainty of peritoneal dialysis machines.
作者 郑辉 龚岚 金鑫 廖旭辉 王苏玲 ZHENG Hui;GONG Lan;JIN Xin;LIAO Xu-hui;WANG Su-ling(Taizhou Institute of Measurement Technology;National Institute ofMeasurement and TestingTechnology)
出处 《中国标准化》 2024年第18期186-191,196,共7页 China Standardization
基金 国家计量技术规范制修订计划项目“腹膜透析机校准规范”(项目编号:23) 台州市第二批工业类科技计划项目“腹膜透析机关键参数检测技术研究及应用”(项目编号:22gyb34)资助。
关键词 腹膜透析 校准 控制温度 透析液容量 留腹时间 称重装置 透析液管 路压力 不确定度 peritoneal dialysis calibration control temperature dialysate volume abdominal retention time weighing device dialysate pipeline pressure uncertainty