期刊文献+

空分装置提氩改造方案的研究

Development of Solution for Argon Revamping in Air Separation Unit
下载PDF
导出
摘要 目前我国西北地区煤化工项目配套的空分装置大多数没有氩产品,而配置了氩增效塔的空分装置中的粗氩气往往被复热排放,没有得到回收利用。结合具体案例提出了3种提氩改造方案,通过对初始投资和运行成本的比较,选择较为经济的解决方案,不但可以优化运行成本,还可以增加液氩产量,具有可观的经济效益。 At present,most air separation units for the coal-chemical industry in our north-west area have no argon product.Some air separation units have a fake argon column,the crude argon is warmed in heat exchanger and blown off,the crude argon has not been recovered.Based on the specific case,this paper proposes three solutions for argon revamping.Through the comparison of the initial equipment investment and operating cost,a more economical solution is selected,which can not only optimize the operating cost,but also yield the liquid argon,and achieve remarkable economic benefits.
作者 付永兴 谢华丽 FU Yongxing;XIE Huali(Airliquide Hangzhou Co.,Ltd.,Hangzhou 310012,China)
出处 《低温与特气》 CAS 2024年第4期28-31,共4页 Low Temperature and Specialty Gases
关键词 空分装置 提氩改造 方案 air separation unit argon revamping solution
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部