摘要
对某火电厂2号锅炉分隔屏管壁超温分析,通过计算加装节流短管,合理分配分隔屏之间流量,解决管壁超温问题。
Base on the analysis of TUBE Wall,over-temperature of No.2 boiler in a thermal power plant.The problem of tube wall over-temperature can be solved by calculating and installing throttling short tube and reasonably distributing the flow between separator screens.
作者
周爽
张磊
ZHOU Shuang;ZHANG Lei(Gujiao Xishan Power Comypany Limitid,Gujiao 030206,China;Changchun Special Equipment Ispaction&Reseach Institute,Changchun 130000,China)
出处
《锅炉制造》
2024年第5期6-7,共2页
Boiler Manufacturing
关键词
分隔屏
节流短管
解决超温
separating screen
throttling spool
to solve the over-temperature