分析了定电位电解法监测糖厂锅炉烟气中SO_2遇到的问题和非分散红外吸收法和紫外差分吸收法的特点,提出对策着力解决监测问题,提高SO_2监测数据可靠性。
This article analyzed the problems encountered in monitoring SO2 in sugar factory boiler flue gas by constant potential electrolysis,and analyzed the characteristics of non-dispersive infrared absorption method and ultraviolet differential absorption method.The countermeasures were proposed to solve the monitoring problems and improve SO2 monitoring data reliability.