摘要
The stability of the magnetic fields is of vital importance to the success of the precision experiments conducted in the experimental Cooler Storage Ring(CSRe)in Lanzhou.In the CSRe,the electromagnets are cooled using room-temperature water.We monitored the magnetic field strength B of one of the dipole magnets,as well as the DC current I of the power supply and the temperature T of the cooling water for a long term.
基金
CAS Young Scholar of Regional Development([2023]15)
CAS Project for Young Scientists in Basic Research(YSBR-002)。