摘要
在深入研究数据中心高压供配电接线架构,并针对双市电与高压柴油发电机的切换逻辑进行细致分析基础上,提出了单路市电停电启动柴油发电机切换逻辑模式,旨在提高柴油发电机的使用效率,同时确保在单路市电供应中断时能够迅速、可靠地切换到柴油发电机供电。这一方案为数据中心提供了更加稳定可靠的电力保障,有效提升了整体系统的运行效率与安全性。
Based on the in-depth study of the high-voltage power supply and distribution wiring architecture of the data center,and the detailed analysis of the switching logic between dual mains supply and high-voltage diesel generator,a logic mode of starting diesel generator switching is proposed for single mains supply blackouts,which aims to improve the efficiency of diesel generator operation,at the same time to ensure that the single mains supply can be switched to diesel generators quickly and reliably when the single mains supply is interrupted.This scheme provides more stable and reliable power guarantee for data center,and effectively improves the efficiency and security of the whole system.
作者
汤维
TANG Wei(Hunan Kangpu Communication Technology Co.,Ltd.,Changsha,Hunan,China 410200)
出处
《湖南邮电职业技术学院学报》
2024年第3期29-33,共5页
Journal of Hunan Post and Telecommunication College
关键词
数据中心
双市电
高压柴油发电机
切换模式
data center
dual mains supply
high-voltage diesel generator
switching mode