摘要
电机性能评价的一个关键指标是定子绕组温升。当电机温升超过标准值时,需从电机结构、冷却器设计、试验方法等多方面去加以分析。本文以解决一台立式异步鼠笼电机温升超标为例,对异步电机的温升计算进行了详细的分析。
A key indicator of performance evaluation of motor is the temperature rise of stator winding.When the motor temperature rise exceeds more than standard value,it is required to analyze from the motor structure,cooler design,test method and other aspects.In this paper,the calculation of the temperature rise of a vertical asynchronous squirrel-cage motor is analyzed in detail.
作者
尚朔
吴磊
吴钊
袁涛
陈建军
SHANG Shuo;WU Lei;WU Zhao;YUAN Tao;CHEN JianJun(Shanghai Electric Machinery Co.,Ltd.,Shanghai 200240,China)
出处
《上海大中型电机》
2024年第3期20-23,共4页
Shanghai Medium and Large Electrical Machines
关键词
异步电机
温升计算
冷却器
Asynchronous motor
Calculation of temperature rise
Air cooler