数据中心柴油发电机冬季保温余热回收系统应用实例研究

Application case study of waste heat recovery systems for winter insulation of diesel generators in data centers
下载PDF
导出
摘要 提出了将北方地区数据中心空调制冷系统余热回收后用于室外柴油发电机缸套水冬季保温,保障柴油发电机快速启动。以实际应用数据中心为案例,介绍了该余热回收系统的设计运行原理、技术路线、具体设计实施方案。对余热回收系统的经济性及节能效果进行了分析,结果表明,柴油发电机保温余热回收系统节能率高达72.1%,年节省运行费用22.67万元,静态投资回收期为3.8 a。该余热回收系统具有初投资低、实施方便、效果显著、收益快的优点,可在北方地区数据中心进行推广。 This paper proposes to recover the waste heat of the air conditioning and refrigeration system of data centers in northern regions and use it for the winter insulation of the jacket water of outdoor diesel generators to ensure the rapid start of diesel generators.Taking an actual application data center as a case,the design and operation principle,technical route,and specific design and implementation scheme of the waste heat recovery system are presented.The economic and energy-saving effects of the waste heat recovery system are analysed.The results show that the energy-saving rate of the diesel generator insulation waste heat recovery system is as high as 72.1%,the annual operation cost savings are 226700 yuan,and the static investment payback period is 3.8 years.This waste heat recovery system has the advantages of low initial investment,convenient implementation,remarkable effect,and quick return.It can be promoted in data centers in northern regions.
作者 高号 沈诚 万雷 Gao Hao;Shen Cheng;Wan Lei(Range Technology Development Co.,Ltd.,Langfang)
出处 《暖通空调》 2024年第10期120-123,127,共5页 Heating Ventilating & Air Conditioning
关键词 数据中心 余热回收 柴油发电机 冬季保温 空调 节能 经济性分析 data center waste heat recovery diesel generator winter insulation air conditioning energy saving economic analysis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部