本文基于电热板消解ICP-MS测定土壤中Cd的测定方法,根据JJF 1059.1-2012检定规程,以测试土壤成分分析标准物质为例,进行不确定度计算与评定。结果表明:该土壤试样Cd含量结果为(0.608±0.048)mg/kg(k=2);前处理样品、标准溶液及配制作为主要贡献分量,分别占32.1%、26.9%。因此,可通过规范的操作减少误差,提高测试结果的精密度和正确度。
In this paper,based on the determination method of Cd in soil by ICP-MS,the uncertainty is calculated and evaluated according to the verification regulations of JJF 1059.1-2012.The results showed that the Cd content of the soil sample was(0.608±0.048)mg/kg(k=2).Pretreatment sample,standard solution and preparation were the main contribution components,accounting for 32.1%and 26.9%respectively.Therefore,the error can be re-duced by standard operation,and the precision and accuracy of test results can be improved.
作者
张钰
涂军
杜颜宏
郭丽
范俊楠
ZHANG Yu;TU Jun;DU Yanhong;GUO Li;FAN Junnan
出处
《计量与测试技术》
2024年第9期20-23,26,共5页
Metrology & Measurement Technique
基金
生态环境部污染物计量和标准样品研究重点实验室开放课题(项目名称:城镇污水处理厂污泥中重金属总量质量控制样品制备技术研究,项目编号:KF202303)。