摘要
本文主要论述了GB/T 6536—2010《石油产品常压蒸馏特性测定法》中使用手动蒸馏测定仪分析车用柴油馏程过程中,95%点回收温度偏高的原因分析与处理措施。通过改进加热方式,优化冷凝管冷凝温度,有效地提高了分析准确度。
In this paper,the reason and treatment measures of high recovery temperature at 95%point in the distillation process of vehicle diesel by using manual distillation tester in GB/T 6536—2010"Standard test method for distillation of petroleum productions at atmospheric pressure".By improving the heating method and optimizing the condensing temperature of the condensing tube,the analysis accuracy is effectively improved.
作者
马贝贝
王浩
张浩
岳洁
MA Beibei;WANG Hao;ZHANG Hao;YUE Jie(PetroChina Ningxia Petrochemical Company,Yinchuan Ningxia 750026,China)
出处
《石油化工应用》
CAS
2024年第9期122-124,共3页
Petrochemical Industry Application
关键词
回收温度
偏高
准确度
recovery temperature
on the high side
accuracy