期刊文献+

摄像水表在二次供水管道漏损控制中的应用

Application of Camera Water Meter in Leakage Control of Secondary Water Supply Pipelines
下载PDF
导出
摘要 采用摄像水表技术对常州通用自来水有限公司小区二次供水管道存量漏损进行监测。结果显示,在2023年7月-9月的2个多月时间里,共发现了20个小区暗漏,每年节约水量641088 m^(3),按照常州水价计算,每年可以节约水费1173191元。摄像水表安装简单、适用性强、价格低,在漏损控制领域具有广阔的应用前景。 The camera water meter technology was used to monitor the leakage of the secondary water supply pipeline in Changzhou General Water Supply Co.,Ltd.The results showed that during the period of more than two months from July 2023 to September 2023,a total of 20 residenial areas were found to have hidden leaks in their pipelines,annual water saving of 641088 m^(3).Based on Changzhou’s water bills,the annual water bill could be saved by 1173191 yuan.The camera water meter has simple installation,strong applicability and low price,and has broad application prospects in the field of leakage control.
作者 高云 俞琦 朱敏 GAO Yun;YU Qi;ZHU Min(Changzhou General Water Supply Co.,Ltd.,Changzhou 320402,China)
出处 《供水技术》 2024年第5期62-64,共3页 Water Technology
关键词 摄像水表 二次供水管道 漏损控制 camera water meter secondary water supply pipeline leakage control