摘要
介绍斯那姆氨汽提工艺尿素高压汽提塔内件运行状态,结合汽提塔腐蚀情况进行原因分析与安全评估,制定并实施了针对性处理措施,保证设备后续运行周期的安全与稳定。
This paper introduced the operation condition of high pressure urea stripper internal in SNAM process.The corrosion analysis and the safety assessment were carried out to establish the corresponding measures for the safety and stability of the equipment operation.
作者
孙喜庆
黄庆祥
柯真
Sun Xiqing;Huang Qingxiang;Ke Zhen(CNOOC Fudao Co.,Ltd.,Dongfang 572600)
出处
《大氮肥》
CAS
2024年第5期343-346,共4页
Large Scale Nitrogenous Fertilizer Industry
关键词
尿素汽提塔
升气管
换热管口
破涡器
urea stripping tower
riser
heat exchange nozzle
vortex breaker