摘要
文章分别对低压开关柜过热故障三线监测系统的硬件设计、软件设计展开了分析,提出硬件设计时,利用光纤式温度监测仪监测低压开关柜,并运用单总线数字式温度传感器读取温度数据。软件系统采用的是多线程编程模式,分别对温度显示控制、温度报警提示、数据通信三项功能进行了设计。最后通过现场安装与调试运行,验证了在线监测系统的稳定性,其功能可以满足电厂变电站低压开关过热故障预控要求,能保障开关柜安全运行。
This article analyzes the hardware and software design of a three line monitoring system for overheating faults in low-voltage switchgear.It is proposed to use a fiber optic temperature monitoring instrument to monitor the low-voltage switchgear during hardware design,and use a single bus digital temperature sensor to read temperature data.The software system adopts a multi-threaded programming mode,which has designed three functions:temperature display control,temperature alarm prompt,and data communication.Finally,through on-site installation and debugging,the stability of the online monitoring system was verified.Its function can meet the pre control requirements for low-voltage switch overheating faults in power plant substations and ensure the safe operation of the switchgear.
作者
周翔
Zhou Xiang(Skill Training Center of Sichuan Electric Power Company of State Grid,Chengdu,China)
出处
《科学技术创新》
2024年第24期67-70,共4页
Scientific and Technological Innovation
关键词
低压开关柜
过热监测
系统设计
low-voltage switchgear
overheat monitoring
system design