摘要
本文主要研究在帐篷类半室外场所空调系统的应用效果。利用CFD模拟分析技术,以位于亚热带季风气候的深圳地区为场所所在地,以地面送风空调器为空调末端,以无风条件和季风条件两种情况为模拟环境,研究在此类场所有/无空调系统、空调末端送风口在室内侧/室外侧、送风角度与水平地面夹角为45°/80°时帐篷内的热环境,并进行对类似工程的实地考察测量,找出在此类场所应用空调系统的弊端,并提出有效的改善措施。
This paper primarily explores the application effect of air conditioning systems in tent-type semi-outdoor spaces.Utilizing Computational Fluid Dynamics(CFD)simulation analysis technology,the study focuses on a location in Shen Zhen,which is situated in a subtropical monsoon climate.It considers ground-level air conditioners as the air conditioning end terminals,simulating two scenarios:no wind conditions and monsoon conditions.The research investigates the thermal environment inside the tent under various conditions,including the presence or absence of air conditioning systems,the positioning of air conditioning end terminals on the indoor or outdoor side,and the angle of airflow delivery relative to the horizontal ground(45°/80°).Field inspections and measurements similar to such engineering projects are conducted to identify drawbacks in the application of air conditioning systems in such spaces and propose effective improvement measures.
作者
廖捷
廖勇坤
LIAO Jie;LIAO Yongkun(Guangdong Architectural Design&Research Institute Co.,Ltd,GuangZhou,510010)
出处
《制冷》
2024年第5期36-42,共7页
Refrigeration
关键词
帐篷
空调系统
CFD模拟
热环境
半室外空调场所
Tent
Air Conditioning System
CFD Simulation
Thermal Environment
Semi-Outdoor Air Conditioning Space