摘要
为了提升末端空调机组换热器在高进出水温度(进水温度10℃,出水温度17℃)下的换热能力,以某一深圳地铁站为例,针对一种高效双级换热器的换热性能展开研究,并基于实验数据,建立双级叉排换热器设计模型,利用CFD技术进行换热器内部流场模拟分析。结果表明,本高效双级换热器设计在高进水温度和大进水水温差下,提升了换热能力,保证了表冷盘管的除湿能力。
In order to improve the heat exchange capacity of the heat exchanger of the terminal air conditioning unit under high inlet and outlet water temperature(inlet temperature 10℃,outlet temperature 17℃),the heat exchange performance of an efficient two-stage heat exchanger was studied in a Shenzhen subway station.Based on the experimental data,the design model of the two-stage cross-row heat exchanger was established.CFD technology is used to simulate the flow field inside the heat exchanger.The results show that the design of the high-efficiency two-stage heat exchanger improves the heat transfer capacity,ensures the dehumidification capacity of the surface cold coil.
作者
顾骞
于德涌
张中安
宋剑伟
王珩
黄云材
谢永健
满余
梁小盈
GU Qian;YU Deyong;ZHANG Zhongan;SONG Jianwei;WANG Heng;HUANG Yuncai;XIE Yongjian;MAN Yu;LIANG Xiaoying(Shenzhen Metro Construction Croup Co.,Ltd.,Shenzhen 518000,China;Shenzhen Metro Croup Co.,Ltd.,Shenzhen 518000,China;Shenzhen Metro Operation Croup Co.,Ltd.,City name Postcode,China;Guangdong Shenling Environmental System Co.,Ltd.,Foshan 528000,China)
出处
《制冷》
2024年第5期43-46,51,共5页
Refrigeration
关键词
双级换热器
地铁空调系统
换热效率
高效节能
经济分析
Two-stage Heat Exchanger
Subway Air Conditioning System
Heat Transfer Efficiency
High Efficiency and Energy Saving
Economic Analysis