期刊文献+

广东地区办公楼多联机系统新风方案探讨

Discussion on Fresh Air Scheme of Multi Split Air Conditioning System for Office Buildings in Guangdong
下载PDF
导出
摘要 本文介绍了多联机空调系统的几种新风方案(常规新风机、热交换新风机组、直膨式新风机组、风冷热泵+组合式新风机组、热泵热回收新风机组等)。同时,以广东地区某办公楼为例,对三种预处理的新风方案系统布置、初投资、运行费用及年运行成本进行了分析,并建议优先采用热泵热回收新风机组,具有较好的推广价值。 This paper introduces several fresh air schemes of multi-line air conditioning system(conventional fresh air fan,heat exchange fresh air unit,direct expansion fresh air unit,air-cooled heat pump+combined fresh air unit,heat pump heat recovery fresh air unit,etc.).Meanwhile,taking a certain office building in Guangdong as an example,the system layout,initial investment,operating cost,and annual operating cost of three pre-treatment fresh air schemes were analyzed,and it was suggested to prioritize the use of heat pump heat recovery fresh air units,which has good promotional value.
作者 朱少林 郭勇 林广都 ZHU Shaolin;GUO Yong;LIN Guangdu(GuangDong Architectural Design&Research Institute Co.,Ltd.,shenzhen,518026)
出处 《制冷》 2024年第5期87-90,94,共5页 Refrigeration
关键词 多联机空调系统 热交换新风机组 热泵热回收新风机组 年运行成本 Multi Split Air Conditioning System Heat Exchange Fresh Air Unit Heat Pump Heat Recovery Fresh Air Unit Annual Operating Cost
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部