摘要 目的建立面前静脉作为自体移植物的大鼠颈总动脉(CCA)动静脉端端吻合训练模型。方法选取24只SD大鼠并随机分为两组,分别进行经典CCA端端吻合(n=12)及面前静脉作为自体移植物的CCA动静脉端端吻合(n=12)。所有吻合均以间断吻合方式进行,建立CCA动静脉端端吻合模型。结果大鼠CCA直径为1.0~1.2 mm,面前静脉直径为0.8~1.0 mm。经典CCA端端吻合约需8~10针,平均吻合时间为(22.75±1.66)min。将面前静脉作为自体移植的CCA动静脉端端吻合组中,每只大鼠需进行2个端端吻合,总吻合时间为(49.42±2.47)min,每个吻合口需8~10针,耗时(24.71±1.65)min。所有吻合口即时通畅率及30 min后通畅率均为100%。结论面前静脉作为自体移植物进行大鼠CCA动静脉微血管端端吻合练习,可模拟血管直径及血管壁厚度均不匹配的端端吻合,该模型为经典CCA端端吻合训练模型的补充。 Objective To establish a training model of common carotid artery(CCA)anastomosis end-to-end in rats with anterior facial vein as autologous graft.Methods Twenty-four SD rats were selected and randomly divided into two groups for classical end-to-end anastomosis of CCA(n=12)and end-to-end anastomosis of CCA with anterior facial vein as autologous graft(n=12).All anastomosis were performed in a discontinuous manner to establish a CCA arteriovenous end-to-end anastomosis model.Results The diameter of CCA in rats was 1.0-1.2 mm,and the diameter of anterior facial vein was 0.8-1.0 mm.The classic CCA end-to-end anastomosis required about 8-10 needles,and the average anastomosis time was(22.75±1.66)min.In the CCA arteriovenous end-to-end anastomosis group with anterior facial vein as autologous graft,each rat needed 2 end-to-end anastomosis,the total anastomosis time was(49.42±2.47)min,each anastomosis required 8-10 needles and took(24.71±1.65)min.The immediate patency rate of all anastomosis and the patency rate after 30 min were 100%.Conclusion The anterior facial vein is used as an autologous graft for rat CCA arteriovenous microvascular end-to-end anastomosis practice,which can simulate end-to-end anastomosis with mismatched vessel diameter and wall thickness.This model is a supplement to the classic CCA end-to-end anastomosis training model.
作者 肖宗宇 汪继 胡蓉 佘孙菊 潘琪 XIAO Zongyu;WANG Ji;HU Rong;SHE Sunju;PAN Qi(Neurosurgery Department,the Fourth Affiliated Hospital of Soochow University(Suzhou Dushu Lake Hospital),Suzhou 215123;Neurosurgery Department,the Second Affiliated Hospital of Guangzhou Medical University,Guangzhou 510260;Dermatology Department,the Eighth Medical Center of PLA General Hospital,Beijing 100091;Neurosurgery Department,Sun Yat-sen Memorial Hospital,Sun Yat-senUniversity,Guangzhou 510120,China)
出处 《临床医学研究与实践》 2024年第33期9-12,共4页 Clinical Research and Practice
基金 国家自然科学基金资助项目(No.82303851) 广东省基础与应用基础研究基金项目(No.2022A1515111065)。
关键词 血管吻合 端端吻合 大鼠 颈总动脉 面前静脉 vascular anastomosis end-to-end anastomosis rat common carotid artery anterior facial vein
  • 相关文献

参考文献2

二级参考文献2

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部