摘要
五桥臂逆变器驱动双三相永磁同步电机(DTP-PMSM)可节约两个功率器件,也可作单相桥臂故障时的容错手段,但五桥臂逆变器驱动下电压利用率(VUF)降低,限制电机调速范围。为拓宽电机调速范围,对五桥臂驱动造成的电压、电流限制进行分析,基于新的电气约束情况,采用电流超前角弱磁控制进行弱磁升速。实验结果表明,电流超前角控制可以平滑进入弱磁I区,有效提升电机最高转速,证明了控制策略的有效性。
The utilization of a five-leg inverter to drive a dual three-phase permanent magnet synchronous motor(DTP-PMSM)can eliminate two power switches,thereby serving as a fault-tolerant mechanism in singe-phase fault conditions.However,the voltage utilization factor(VUF)reduces under this five-bridge inverter,ultimately limiting the motor’s speed range.To address this limitation,a analysis was conducted regarding the voltage and current constraints imposed by the five-bridge inverter.Subsequently,a current phase advancing based flux-weakening control was adopted to achieve the speed extension.The experimental results demonstrate this current phase advancing control facilitate a seamless transition into the flux-weakening I zone,significantly elevating the motor’s maximum speed,thereby validating the effectiveness of the proposed method.
作者
徐晟
王磊
田兵
王涛
XU Sheng;WANG Lei;TIAN Bing;WANG Tao(College of Automation,Nanjing University of Aeronautics and Astronautics,Nanjing 210016,China;College of Electrical Engineering,Zhejiang University,Hangzhou 310027,China;不详)
出处
《微电机》
2024年第11期12-17,共6页
Micromotors
基金
航空基金学会(2022Z024052002)
中央高校基本科研业务费专项资金资助项项(NJ2023012,NJ2023014)。
关键词
五桥臂逆变器
双三相永磁同步电机
电流超前角控制
five-leg inverter
dual-three phase permanent magnet synchronous motor
lead angle flux-weaking control