摘要
针对电压闪变信号提取不准确的问题,提出一种基于广义S变换的电压闪变检测法。通过引入α变量改变S变换窗函数的窗宽,局部调整S变换频域和时域测量精度,从而实现电压闪变精确检测。实验结果表明,与传统S变换方法相比,该方法准确率高,能更有效检测出电压闪变成分。
In view of the inadequate accuracy in the extraction of voltage flicker signals,this work tentatively proposed a generalized S-transform-based voltage flicker detection method.The method was designed to introduceαvariables to change the width of S-transform window function,and to locally adjust frequency and time resolution of S-transform,hence realizing accurate detection of voltage flicker.The proposed method was indicated by experiment to be superior in accuracy compared with the conventional S-transform method and competitive in effectively detecting voltage flicker.
作者
吴启宇
张安婷
俞明
WU Qiyu;ZHANG Anting;YU Ming(Nanjing Lishui District Power Supply Branch of State Grid Jiangsu Electric Power Co.,Ltd.,Nanjing 211200,China;Nanjing Sanxin Power Supply Service Co.,Ltd..Lishui Branch,Nanjing 211299,China)
出处
《电工技术》
2024年第21期88-91,共4页
Electric Engineering
关键词
电压闪变
广义S变换
窗函数
闪变检测
voltage flicker
generalized S-transform
window function
voltage flicker detection