建立了镍氢电池正极材料氢氧化亚镍中主成分锌、钴及杂质钙、镁、锰、镉的ICP AES测定方法。选择了仪器最佳工作条件 ,研究了镍基体对被测元素的干扰。方法的回收率为 95 .9%~ 1 0 3% ,RSD为 0 .93%~ 1 8%。
The determination of Zn, Co, Ca, Mg, Mn, Cd in nickel hydroxide was realized by inductive coupled plasma optical emission spectrometry(ICP AES). Recovery of the method was between 95.9%~103%, and RSD was between 0.93%~18%?