摘要 本文介绍一种新型的血压Holter,它将微处理器控制的血压检测模块与掌上电脑结合实现血压数据的自动监测和远程传输。血压检测采用振动测量法原理 ,由微处理器控制气泵、气阀开关 ,实现袖套的充放气 ,袖套内压力信号经压力传感器检测、放大和滤波后由A D转换器采集 ,通过串口传给掌上电脑进行分析处理 ,确定血压参数。掌上电脑还兼具参数设置、波形浏览、参数统计与远程传输等功能。本研究借助移动计算技术 ,较好地解决了现有设备因缺乏远程传输能力而应用范围受限的问题 ,可望广泛地用于社区诊所、家庭病房、医院等多种场合血压信息的收集 ,应用前景十分广阔。 In this paper is described a novel pressure Holter, which combines a microprocessor\|controlled blood pressure detecting module with a palm PC to implement remote data transfer capability. In detail, using the oscillometric method, a gas\|discharging procedure is implemented in the sleeve by controlling ON and OFF of the pump and value respectively. Meanwhile, the pressure signal in the sleeve is detected by a pressure sensor and then amplified and filtered to reject noise and to extract blood pressure oscillation wave. A/D converters digitize the pressure signals and send them to palm PC for analysis, determining the blood pressure parameters. Additional functions, such as interactive parameter setting, waveform browsing, statistics of parameters, and remote data transferring, are implemented by using the palm PC. By mean of mobile computing technology, this study has overcome the application limitation suffered by those currently available devices due to lack of remote data transfer capability. It is expected to widely apply it for acquisition of blood pressure information in many situations, including community clinic, family and hospital.
出处 《北京生物医学工程》 2002年第4期252-255,共4页 Beijing Biomedical Engineering
基金 国家 8 63计划资助 (No . 863 -3 0 6-ZD13 -0 5-2 )
关键词 血压 远程监护 掌上电脑 Blood pressure Telemonitoring Palm personal computer(PPC)
  • 相关文献

参考文献4

二级参考文献13

  • 1甄斌,孙咏梅,巩欣洲,万明习.便携式血压HOLTER系统的研制[J].中国医疗器械杂志,1996,20(6):333-336. 被引量:5
  • 2王鹏巨 杨原茂 等.用示波法实现动脉血压的自动检测[J].医疗器械,1987,12(2):79-79.
  • 3邹理和.数字信息处理(上)[M].国防工业出版社,1985..
  • 4邓卫中,北京生物医学工程,1993年,12卷,4期,225页
  • 5齐颁扬,医学仪器.上,1990年
  • 6王鹏巨,医疗器械,1987年,12卷,2期,79页
  • 7邹理和,数字信号处理.上,1985年
  • 8王鹏巨,杨原茂,田孝文,周山宏.用示波法实现动脉血压的自动检测[J]医疗器械,1987(02).
  • 9Maynard Ramsey. Automatic Oscillometric NIBP Versus Manual Auscultatory Blood Pressure in the PACU[J] 1994,Journal of Clinical Monitoring(2):136~139
  • 10Maynard Ramsey MD,PhD. Blood pressure monitoring: Automated oscillometric devices[J] 1991,Journal of Clinical Monitoring(1):56~67