摘要 介绍了开发设计的计算机心肌核素断层显像定量分析系统。该系统可进行原始数据的读取和格式转换 ,自动分割左心室 ,完成SPECT心肌灌注靶心图定量分析、PET心肌代谢靶心图定量分析 ,对病人数据进行 9分区靶心图定量计算等临床数据处理任务。并将结果同医师半定量诊断结果进行对比。 A quantitative analysis system of myocardial radionuclide tomographic imaging (SPECT and PET) was developed. The system can be used for quantitative analysis of myocardial radionuclide tomographic imaging. This system can read the clinical original data, change data format, segment image of LV automatically, and can carry out myocardial injection polar map quantitative analysis, PET myocardial metabolism polar map quantitative analysis, and other quantitative calculations, such as 9 sub region polar map of patients′ clinical data. The results obtained with this system were compared with semi quantitative diagnosis of doctors.
出处 《北京生物医学工程》 2002年第4期260-263,共4页 Beijing Biomedical Engineering
基金 国家攀登计划项目资助 (B85 -4 5 -0 3 -3 )
关键词 SPECT PET 心肌核素断层显像 定量分析 SPECT PET Myocardial radionuclide imaging Quantitative analysis
  • 相关文献

参考文献2

二级参考文献3

  • 1赵书俊 刘力 等.-[J].国外医学--放射医学核医学分册,1998,22:108-112.
  • 2赵书俊,国外医学.放射医学核医学分册,1998年,22卷,108页
  • 3Germano G,J Nucl Med,1995年,36卷,1107页

共引文献11

同被引文献21

  • 1周颖,何青,屈婉莹,高文萍,朱明,赵洪山,周清华,高天科.^(99m)Tc-MIBI门控心肌断层显像同时评价心肌灌注和左室功能[J].中华核医学杂志,1995,15(2):87-89. 被引量:20
  • 2Lancaster JL,Starling MR,Kopp DT,et al.Effect of errors in reangulation on planar and tomographie thanium-201 washout profile curves.J Nucl Med ,1985,26:1445-1455.
  • 3DePuey EG,Garcia EV.Optimal specificity of thaUium-201 SPECT through recognition of imaging artifacts.J Nucl Med,1989,30:441-449.
  • 4DePuey EG,Garcia EV.Updated imaging guidelines for nuclear cardiology procedures,Part 1.Journal of Nuclear Cardiology,2001,8 (1):GS-G58.
  • 5Germano G,Kavanagh PB,Su HT,et al.Automatic reorientation of three-dimensional tnmsaxial myocardial perfusion SPECT images.J Nucl Med,1995,36:1107-1114.
  • 6Van Train KF, Areeda J, Garcia EV, et al. Quantitative same-day rest - stress Technetium - 99m - sestamibi SPECT: Definition and validation of stress normal limits and criteria for abnormality[J]. J Nucl Med, 1993,34:1494-1502.
  • 7Toft J, Hesse B, Rabol A, et al. The occurrence of false - positive technetium - 99m - sestamibi bull's eye defects in different reference database: a study of an age - and gender - stratified healthy population[J]. Eur J Nucl Med, 1997,24 : 179-183.
  • 8Garcia EV, Cooke CD, Van Train KF, et al. Technical aspects of myocardial SPECT imaging with Technetium - 99m - sestamibi[J]. Am J Cardiol, 1990,66:23E-31E.
  • 9Roberto S,Alessio I,David A,et al.Relationship of infarct size and severity versus left ventrieular ejection fraction and volumes obtained from 99mTc-sestamibi gated SPECT in patients treated with primary percutaneous coronary intervention.J Nucl Med Mol Imaging,2004;31:969
  • 10Christian V,Natasha W,Frank DG,et al.Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction.J Nucl Med,2002;29:735

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部