期刊文献+

硅微通道法测量红细胞变形性的双参数模型 被引量:3

A Dual-paramater Model for Assessing Red Blood Cell Deformability Using Silicon Microchannels Method
下载PDF
导出
摘要 本文对硅微通道法测量红细胞变形性的理论进行了针对性的分析和推导 ,提出了在硅微通道法中以细胞通过阻力 β和细胞堵塞比率ε分析红细胞变形性的双参数方法 ,并结合我们利用该技术研制的红细胞流变性测量芯片系统进行实验研究 。 Silicon microchannels method is novel and effective one for assessing red blood cell deformability.In this special way,we developed a quantitative analysis model with two parameters.Two intuitive parameters of RBC deformability(i.e.RBC average transit resistance β and proportion ε of RBC clogging)were extracted based on this model.Then we took advantage of a silicon microchannels chip system for studying RBC rheological characteristics to do some experiments to prove the applicability of this theoretical method.
出处 《北京生物医学工程》 2002年第4期264-267,共4页 Beijing Biomedical Engineering
关键词 双参数模型 硅微通道 红细胞变形性 通过阻力β 塞比率ε Silicon microchannels\ \ RBC deformability\ \ RBC average transit resistance β\ \ Proportion ε of RBC clogging
  • 相关文献

参考文献2

二级参考文献4

共引文献11

同被引文献25

  • 1许锋,胡林,肖文波.血液流变学中影响红细胞变形性的因素分析[J].贵州大学学报(自然科学版),2004,21(3):279-281. 被引量:14
  • 2文宗曜.红细胞变形性测定[J].生理科学进展,1989,20(4):339-343. 被引量:2
  • 3易仁亮,邹霞英.红细胞变形性的影响因素[J].中国病理生理杂志,1995,11(6):658-659. 被引量:12
  • 4姜海,郑小林,彭承琳,翁璇.基于MEMS技术的红细胞变形性测量系统的研究[J].中国医疗器械信息,2006,12(12):28-31. 被引量:2
  • 5Baskurt OK,Meiselman HJ.Blood Rheology and Hemodynamics[J].Seminars in Thrombosis and Hemostasis,2003,29(5):435-450.
  • 6Caimi G,Lo Presti R.Techniques to evaluate erythrocyte deformability in diabetes mellitus[J].Acta Diabetologica,2004,41(3):99-103.
  • 7Singh M,Stoltz JF.Influence of temperature variation from 5℃ to 37℃ on aggregation and deformability of erythrocytes[J].Clinical Hemorheology and Microcirculation,2002,26(1):1-7.
  • 8Bas kurt OK,Mat F.Importance of measurement temperature in detecting the alterations of red blood cell aggregation and deformability studied by ektacytometry:A study on experimental sepsis in rats[J].Clinical Hemorheology and Microcirculation,2000,23(1):43-49.
  • 9Jagger J,Ellis CG,Sibbald WJ.Measurement temperature plays a pivotal role in the distribution of erythrocyte deformability afterLPS[J].Biorheology,2001,38(5-6):439-448.
  • 10La Celle PL,Smith BD.Biochemical factors influencing erythrocyte deformability and capillary entrance phenomena[J].Scandinavian Journal of Clinical and Laboratory Investigation,1981,41(Suppl.156):145-149.

引证文献3

二级引证文献21

相关作者

内容加载中请稍等...