摘要 对变压器中绝缘油流动带电现象进行了研究,给出了一些大型变压器运行故障实例,分析了变压器静电起电的原因和条件,介绍了静电起电的监视技术。 The electrification in transformer oil is researched.Some fault examples in transformer operation are given.The reasons and conditions in static electrification of transformers are ana-lyzed.The monitoring technique of static electrification is introduced.
作者 顾宏
出处 《变压器》 北大核心 2002年第12期23-25,共3页 Transformer
关键词 电力变压器 静电起电 监视 静电荷 Transformer Static electrification Reason Condition