期刊文献+

甜橙贮藏过程香气成分变化 被引量:1

CHANGES IN THE VOLATILE FLAVOR CONSTITUENTS OF CITRUS SINENSIS(L.)OSBECK DURING STORAGE
全文增补中
导出
摘要 用气相色谱 Kováts 保留指数,色-质联用等方法,研究了甜橙 Citrus sinensis(L.)Osbeck果皮精油化学成分及甜橙果肉香气浓缩物化学成分。从甜橙果皮精油中鉴定出29个成分,从甜橙果肉香气浓缩物中鉴定出40个成分,其中微量成分α-甜橙醛、β-甜橙醛是甜橙特征香气成分;探讨了甜橙贮藏过程果皮与果肉香气成分变化。 The methods of GC with fused silica capillary column,its Kovats reteion index of GC and GC-MS-DS etc.We were used to study thc aromatic compounds of the peel essential oil of Citrus sinensis (L) Osbeck and aromatic concentrates of fruit flesh.29 chemical constituents from the peels and 40 chemical constituents from the fruit flesh were identified.The trace con- stituents α-sinensal 0.01% and β-sinensal 0.01% are the special aroma ones for Citrus sinensis. At the same time,the changes flavor components in Citrus sinensis peels and fruit flesh during storage were also explored.
出处 《Acta Botanica Sinica》 1988年第6期623-628,共6页 Acta Botanica Sinica(植物学报:英文版)
关键词 贮藏过程 香气成分 甜橙 色-质联用 保留指数 成分变化 Citrus sinensis Essential oil Aroma concentrates of fruit flesh GC-MS Retention index
  • 相关文献

同被引文献25

  • 1丁利君,任乃林,周燕芳,张亮鹏,谢世江,张木生.番荔枝果肉营养成分分析[J].营养学报,2006,28(3):275-276. 被引量:32
  • 2余艳锋,祁春节.中国甜橙国际竞争力实证分析[J].新疆农垦经济,2007(7):13-19. 被引量:8
  • 3Arena E, Guarrera N, Campisi S, Nicolosi C A. Comparison of odour active compounds detected by gas-chromatography - olfactometry between hand-squeezed juices from different orange varieties[J]. Food Chemistry, 2006, 98( 1 ) : 59 -63.
  • 4Wohltjen l-I, DessyR. Surface Acoustic Wave Probe for Chemical Analysis. I. Introduction and Instrument Description[ J]. Analytical Chemistry, 1979, 51 (9) : 1458 - 1464.
  • 5Hoyt A E, Ricco A J, Bartholomew J W, Osbourn G C. SAW sensors for the room-temperature measurement of CO2 and relative humidity[ J]. Analytical Chemistry, 1998, 70 (10) : 2137 - 2145.
  • 6Atashbar M Z, Sadek A Z, Wlodarski W, Sriram S, Bhaskaran M, Cheng C J, Kaner R B, Zadeh K K. Layered SAW gas sensor based on CSA synthesized polyaniline nanofiber on AIN on 64 YX I,iNbO3 for H2 sensing[J]. Sensors and Actuators Chemical, 2009, 138 (1): 85-89.
  • 7Shen C Y, Huang C P, Huang W T. Gas-detecting properties of surface acoustic wave ammonia sensors [ J]. Sensors and Actuators Chemical, 2004, 101(1-2): 1-7.
  • 8Caliendo C, Fratoddi I, Russo M V. Sensitivity of a platinum- polyyne-based sensor to low relative humidity and chemical vapors[ J]. Applied Physics Letters. 2002, 80(25) : 4849 -4851.
  • 9Leidl A, Hartinger R, Ruth M, Endres H E. A new SO2 sensor system with SAW and IDC elements [ J ]. Sensors and Actuators Chemical, 1996, 34(1 -3): 339-342.
  • 10Du X S, Ying Z H, Jiang Y D, Liu Z X, Yang T J, Xie G Z. Synthesis and evaluation of a new polysiloxane as SAW sensor coating for DMMP detection[J]. Sensors and Actuators Chemical, 2008, 134(2): 409 -413.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部