在分析线路过载现象产生原因的基础上,对移相变压器的选址问题进行了研究,提出了能反映移相变压器调控效果与安装位置有关的绝对指标和相对指标的概念以及选址方法。对某省实际电力系统典型运行方式下的移相变压器进行了选址分析,结果表明,应用文中所提的指标和方法可以准确地确定移相变压器的安装位置。
On the basis of analyzing the reasons causing the overload of transmission lines, one of the effectivecountermeasures, i.e., the site selection of phase-shifter, isresearched. The index and the method for site selection based on proper sensitivity analysis are put forward. The analysisresult of site selection for practical power system in a certain domestic province under the typical operating modes showsthat with the presented index and method of site selection the installation position of phase-shifter can be accuratelydetermined.