摘要
本文研究了用电热和超声雾化两种进样方法以MIPAES(微波诱导等离子体原子发射光谱)对银的测定,并详细考查了实验条件。两种方法对银的检出限分别为1.5ng/ml和1.0ng/ml。
Two methods of sample introduction-electrothermal and ultrasonic wave nebulizing are compared through experiment to determine silver by MIP-AES. The respective detection limits of 1.5ng/ml and 1.0μg/ml are obtained for the two methods.
出处
《黄金》
CAS
北大核心
1989年第7期33-36,共4页
Gold
关键词
银
电热
超声雾化
原子发射光谱
Electrothermal and ultrasonic wave nebulizing
Atomic emission speq-trometry, Silver