摘要该文介绍了用超高频法监测气体绝缘道电缆内部局部放电的基本原理、应用及抗干扰能力。The principle, application and anti-interference of the UHF method for PD detection of gas insulated cables are presented.
4Baumgartner R et al. Partial discharge part XI:PD in gas-insulated substations-Fundamental considerations. IEEE EIM, 1991,7(6):5.
5Pearson J S et al. A continuous UHF monitor for gasinsulated substations, IEEE Trans EI,1991, 6(3):469.
6Nichdas de Kock et al. UHF PD detection in gas-insulated switchgear-suitablity and sensitivity of the UHF method in comparison with the IEC 270 method.IEEE EIM,1996,12(6):20.
7Zhang M C et al. Wide bandwidth sensor for PD measurement in GIS. 3rd Internatinal Conference of ECAAA, Xian China, 1996.