期刊文献+

水平管空气-水段塞流冷却传热研究 被引量:2

Heat Transfer in Cooling Process of Air-Water Slug Flow in Horizontal Pipe
原文传递
导出
摘要 段塞流的流动与传热现象存在于许多工业应用领域.本文在长12m、内径26mm的水平管上进行冷却条件下空气-水气液两相段塞流流动与传热的实验研究.采用电导探针、热电偶等测试手段测量段塞流的流动与传热参数,分析了冷却条件下段塞流对流传热系数随两相流压降、气液表观流速等参数的变化规律. Slug flow and heat transfer occurs in many industrial applications.The experimental study of air-water slug flow and heat transfer in cooling process has been carried out in horizontal pipe.The length of the test section pipe is 12 m with inner diameter 26 mm.The techniques of conductivity probe and thermalcouple were applied in the experiment to measure the slug flow and convective heat transfer parameters.The influence of two-phase pressure drop,superficial gas and liquid velocities on slug flow heat transfer coefficient is discussed.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2014年第8期1563-1568,共6页 Journal of Engineering Thermophysics
基金 国家自然科学基金(No.51376197) 山东省自然科学基金项目(No.ZR2011EEM029) 西安交通大学动力工程多相流国家重点实验室与中央高校基本科研业务费专项资金(No.09CX04021A)
关键词 两相流 段塞流 对流换热 传热系数 two-phase flow slug flow convective heat transfer heat transfer coefficient
  • 相关文献

参考文献2

  • 1G. Sun,G.F. Hewitt,V.V. Wadekar.A heat transfer model for slug flow in a horizontal tube[J].International Journal of Heat and Mass Transfer.2003(12)
  • 2G. Hetsroni,J.H. Yi,B.G. Hu,A. Mosyak,L.P. Yarin,G. Ziskind.Heat transfer in intermittent air–water flows—Part II[J].International Journal of Multiphase Flow.1998(2)