摘要
上海合景国际广场紧邻黄浦江边,为钢管混凝土框架-混凝土核心筒结构,其特点一是核心筒严重偏置,质心与刚心严重偏离,扭转效应显著,筒外办公区钢梁跨度20m;二是2层楼面有效宽度小于本层宽度的40%,属于超限结构。文中采用SATWE、ETABS及PMSAP进行了小震计算与复核,采用PUSH&EPDA对结构进行了罕遇地震下的静动力弹塑性分析,根据计算结果采取加强措施,使本工程达到了抗震设计性能目标。
Shanghai KWG International Plaza is beside the Huangpu River. It's steel frame-concrete core wall structural system. Structure has the following characteristics:the concrete core wall is biasing to the building one side. The eccentricity of structural mass center and rigid center is increasing,and torsional effect is significant. And the span of office area is up to 20 m. On the other hand,the effective width of second floor is less than 40% of the floor. So the building belong to the ultra limit complicated structure. SATWE,ETABS and PMSAP are utilized to calculate and check frequently occurred earthquake. And PUSH&EPDA is utilized to establish a whole structure analysis model,the elastic-plastic pushover and time-history analysis shall be carried out under the rare earthquake. According to the result,some technical measures have been adopted to assure the seismic performance of this building.
出处
《广东土木与建筑》
2015年第2期3-7,共5页
Guangdong Architecture Civil Engineering
关键词
偏置核心筒
超限高层
楼板舒适度
钢管混凝土跃层柱
钢支撑
remote-center core wall
high-rise building beyond code limited
floor comfort
CFST column
steel brace